#CEC Biosafety Cabinet Class II A2/B2, BSC-SERIES

BIOSAFETY · #CEC

Biosafety Cabinet Class II A2/B2

Model: BSC-SERIES

Catalogue applications include plant and human pathogen isolation and identification, virology, tissue culture, sterility testing and recombinant DNA research. Mild-steel powder-coated outer body, negative-pressure dynamic chamber, HEPA-filtered integral exhaust system, front sliding door with arm rest, positive air curtain, UV light and gas cock as applicable, and lockable castor wheels. Catalogue lists A2/B2 options without assigning a type to individual model numbers. Ensure adequate door and laboratory-room dimensions, workers for unloading, and industrial lift support if the laboratory is above the ground floor.

Reference specifications

These are the catalogue reference specifications. Use the model comparison below for the exact variant.

  • Internal dimensions (W × D × H): 600 × 600 × 678 mm
  • Nominal working size (W × D × H): 2 × 2 × 2 ft
  • HEPA filter size (W × D × H): 2 ft × 1.5 ft × 6 in
  • HEPA filters: 1
  • Illumination: 1 × 20 W
  • Work surface: stainless steel 304 perforated working table
  • A2 option: 70% recirculated / 30% exhaust (catalogue statement)
  • External laboratory exhaust connection: optional; required for Class II B2
  • Mobility: lockable castor wheels

Choose a variant

#CEC Biosafety Cabinet Class II A2/B2, BSC-SERIES shown for BSC322

Selected variant

BSC322

Model / SKU
BSC322
Availability
Confirm availability
Price
Request quotation

Catalogue applications include plant and human pathogen isolation and identification, virology, tissue culture, sterility testing and recombinant DNA research. Mild-steel powder-coated outer body, negative-pressure dynamic chamber, HEPA-filtered integral exhaust system, front sliding door with arm rest, positive air curtain, UV light and gas cock as applicable, and lockable castor wheels. Catalogue lists A2/B2 options without assigning a type to individual model numbers. Ensure adequate door and laboratory-room dimensions, workers for unloading, and industrial lift support if the laboratory is above the ground floor.

  • Internal dimensions (W × D × H): 900 × 600 × 678 mm
  • Nominal working size (W × D × H): 3 × 2 × 2 ft
  • HEPA filter size (W × D × H): 3 ft × 1.5 ft × 6 in
  • HEPA filters: 1
  • Illumination: 2 × 40 W
  • Work surface: stainless steel 304 perforated working table
  • A2 option: 70% recirculated / 30% exhaust (catalogue statement)
  • External laboratory exhaust connection: optional; required for Class II B2
  • Mobility: lockable castor wheels

Availability can change. Your quotation confirms quantity and dispatch timing.

Laboratory equipment supplied across India

Chemo Equip Corporation supports colleges, universities, hospitals, pharmaceutical companies, research laboratories and industry with technical selection, institutional quotations and dependable after-sales service.